Error and Status Communication from Harmony to Automation Software

What is the challenge? Harmony does not properly communicate Error messages (e.g. due to Focus Errors) to the Integrator's automation software. What is the impact? In an automated environment, the customer needs to see all issues related to their ...
Guest about 3 hours ago in Harmony 0

Make Heat Map Display interactive

What is the challenge? Selecting wells that have interesting results visible on the heat map. This is not possible. In contrast to all other plate displays and even the Graph Display, the Heat Map on the evaluation tab does not allow to select wel...
Guest about 1 month ago in Harmony 0

Copy/Past of Heat Maps

What is the challenge? After an analysis including a Heat Map into a demo report is a hassle. One has to save it to disk and then import it into the report. And the saved image has a rubbish canvas. Harmony shows all the wells in the same size, so...
Guest about 1 month ago in Harmony 0

Better Labels in Plate Overviews

What is the challenge? The labels in our plate overviews are "suboptimal". If we read 4 fields in a 384 well plate we get either no label ... and we have to count rosw/columns small ... in every well we get for each field one label like "M23:4" wh...
Guest about 1 month ago in Harmony 0

Adapt the z-Volume of a Re-Scan (PreciScan in Z) to the size of the Re-Scanned Object

What is the challenge? PreciScan in Z is a powerful tool to image e.g. organoids. However, usually the organoids are very diverse in size. This means that A) the scientist needs to know quite precisely the size of the largest objects of interest, ...
Guest about 2 months ago in Harmony 0

When measuring default to "µm" instead of "pixel"

What is the challenge? Usability: when working with images in Harmony distances are usually entered in µm and also users think of µm. However, when measuring something interactively in Harmony, it always defaults to pixel ... on every image displa...
Guest about 2 months ago in Harmony 0

Meaningful sequence of results also for the first graph

What is the challenge? After the analysis the sequence of results by default follows the sequence the wells were measured. And this is very counter-intuitive and leads to initial mis-interpretations. E.g. the results for the Wells B5, C5 and D5 ar...
Guest about 2 months ago in Harmony 0

Archiving PreciScan Measurements

When writing archives of PreciScan measurements always include the evaluation of Measurement "a" that was used to find the regions. When archiving only measurements these evaluations are often forgotten and later on the connection between the two ...
Guest 3 months ago in Harmony 0

Evaluations don't show, which fields/planes were evaluated

If multiple Fields / and Planes in a MaxProjection have been evaluated, there is currently not really a way for the users to know, from which fields and planes the results come from. They are only informed "Number of evaluated fields: 4". But not ...
Guest 3 months ago in Harmony 0

More tools for creating related populations

Sometimes it is necessary to detect objects of different types independently. E.g. nuclei and cells. And then we want to work in Harmony image analysis with the cells-nuclei combination. Currently there is no tool to assign "nuclei" to the "cell" ...
Guest 3 months ago in Harmony 0